Welcome to the Fieldpiece Vacuum Pump Manual, your comprehensive guide to operating and maintaining models VPX7, VP87, and VP67. This manual provides essential safety, features, and usage instructions for optimal performance and longevity.

Important Notices and Warnings

Read this manual thoroughly before using the vacuum pump. Adhere to all safety guidelines to prevent injury or equipment damage. Dispose of the pump and oil responsibly, following environmental regulations and safety standards.

Safety Precautions

To ensure safe operation of the Fieldpiece Vacuum Pump, follow these critical guidelines:

  • Always wear protective eyewear and gloves when handling the pump or performing maintenance.
  • Avoid touching hot surfaces, as the pump may become hot during operation.
  • Ensure proper ventilation in the work area to prevent inhalation of fumes or oil mist.
  • Keep children and unauthorized individuals away from the equipment.
  • Never operate the pump near open flames or sparks, as flammable vapors may be present.
  • Use only Fieldpiece-approved oil to avoid contamination and ensure optimal performance.
  • Disconnect the pump from power before performing any maintenance or oil changes.
  • Follow all local and national safety regulations when disposing of used oil and filters.
  • Do not modify or tamper with the pump’s design, as this may void the warranty and create safety hazards.

By adhering to these precautions, you can minimize risks and ensure safe, efficient operation of your Fieldpiece Vacuum Pump.

Environmental Considerations

Fieldpiece Vacuum Pumps are designed with environmental responsibility in mind. Proper handling and disposal of materials are essential to minimize their ecological impact. Always use Fieldpiece-approved vacuum pump oil, as it is formulated to reduce contamination risks. Dispose of used oil, filters, and other waste according to local, state, and federal regulations to prevent environmental harm.

  • Recycle materials whenever possible, such as metal components and packaging.
  • Avoid releasing refrigerants or other substances into the atmosphere, as they may contribute to ozone depletion or climate change.
  • Ensure the pump is operated within specified temperature and humidity ranges to maintain efficiency and reduce energy consumption.
  • Regularly inspect and maintain the pump to prevent leaks or excessive noise, which could disturb nearby ecosystems.

By following these guidelines, users can help protect the environment while ensuring the longevity and performance of their Fieldpiece Vacuum Pump.

Features and Specifications

The Fieldpiece Vacuum Pump offers advanced features like the RunQuick Oil Change System, high CFM ratings (6CFM to 10CFM), and dual voltage options. Its lightweight, portable design includes a large oil reservoir window for easy monitoring.

Key Features of the Fieldpiece Vacuum Pump

The Fieldpiece Vacuum Pump stands out with its innovative RunQuick Oil Change System, enabling quick and clean oil replacements without tools. It boasts high CFM ratings, ranging from 6CFM to 10CFM, ensuring efficient system evacuations. The pump’s portable and lightweight design makes it easy to transport to various job sites. Additionally, the large oil reservoir window provides clear visibility, allowing users to monitor oil levels effortlessly. Dual voltage options cater to different power requirements, enhancing versatility. The pump is designed for optimal performance in HVACR applications, supporting up to 50 tons of cooling capacity; Safety features include thermal protection and durable construction to withstand demanding environments. These features collectively make the Fieldpiece Vacuum Pump a reliable and efficient tool for professionals needing precise and rapid vacuum operations.

Technical Specifications

The Fieldpiece Vacuum Pump models VPX7, VP87, and VP67 are engineered for high performance and durability. They offer a maximum vacuum level of 29.9 inHg and operate within a temperature range of 32°F to 122°F (0°C to 50°C). The pump’s oil capacity is optimized for extended operation, ensuring minimal downtime. With a low noise level of approximately 60 dBA, it provides a quiet working environment. Designed for versatility, these pumps are compatible with a wide range of refrigerants and systems. The durable construction includes a stainless steel valve and a robust motor for long-term reliability. Each model is certified to UL and CSA standards, ensuring safety and compliance with industry regulations. These technical specifications make the Fieldpiece Vacuum Pump a dependable choice for HVACR professionals, delivering consistent performance across various applications.

Models and Variants

The Fieldpiece Vacuum Pump is available in multiple models, including the VPX7, VP87, VP67, and their international variants like VPX7UK and VP87UK. Each model is tailored for specific applications, ensuring optimal performance across various HVACR systems and environments.

VPX7 Model Details

The VPX7 model is a high-performance vacuum pump designed for efficient system evacuations. It features a 10 CFM flow rate, making it suitable for large HVACR systems, including those over 50 tons. The pump is lightweight and portable, with a robust design that ensures durability. One of its standout features is the RunQuick Oil Change System, which allows for quick and clean oil changes, minimizing downtime. The VPX7 also includes a large oil reservoir window for easy oil level monitoring. Safety features include thermal protection and a secure vacuum gauge port. It operates within a wide temperature range, ensuring reliability in various environments. The VPX7 is ideal for technicians needing a powerful, reliable, and user-friendly vacuum pump for demanding applications. Always use Fieldpiece-approved oil to maintain optimal performance and longevity of the pump.

VP87 Model Details

The VP87 model is a powerful and versatile vacuum pump, offering an 8 CFM flow rate, making it ideal for medium to large HVACR systems up to 30-50 tons. Designed for efficiency, it features the innovative RunQuick Oil Change System, enabling quick and clean oil changes without tools. The pump is lightweight yet durable, ensuring portability and reliability in field applications. It includes a large oil reservoir window for easy oil level monitoring and a secure vacuum gauge port for precise measurements. The VP87 also incorporates thermal protection to prevent overheating and extends pump life. With its robust design and advanced features, this model is perfect for technicians requiring consistent performance in demanding environments. It meets international safety standards, including UL and CE certifications, ensuring safe and reliable operation. The VP87 is compatible with a wide range of refrigerants and systems, making it a versatile choice for HVACR professionals.

VP67 Model Details

The VP67 model is a compact and efficient vacuum pump, offering a 6 CFM flow rate, suitable for small to medium HVACR systems up to 30 tons. It features the RunQuick Oil Change System for easy maintenance, allowing technicians to change oil quickly without tools. The pump’s lightweight design enhances portability, making it ideal for field use. A clear oil reservoir window ensures easy monitoring of oil levels, and the pump includes thermal protection to prevent overheating. The VP67 meets safety standards such as UL and CE certifications, ensuring reliable operation. It supports a wide range of refrigerants and is compatible with various system configurations. With its balance of performance and portability, the VP67 is a practical choice for HVACR professionals needing a dependable vacuum pump for smaller applications. Its compact size and efficient operation make it a favorite among technicians who value ease of use and consistent results.

Using the RunQuick Oil Change System

The RunQuick Oil Change System allows for easy and quick oil changes without tools, minimizing downtime; Simply release the drain valve, replace the oil, and resume operation. This feature ensures optimal pump performance and longevity.

Troubleshooting Common Issues

If your Fieldpiece Vacuum Pump isn’t performing as expected, check for common issues like low vacuum performance or slow recovery times. Ensure the pump is properly oiled with fresh Fieldpiece Vacuum Pump Oil, as old or contaminated oil can reduce efficiency. Verify all connections are secure and free from leaks. If the pump fails to start, inspect the power source and ensure the cord is undamaged. For models with the RunQuick Oil Change System, confirm the oil reservoir is at the recommended level. If issues persist, refer to the troubleshooting guide in the manual or contact Fieldpiece support for assistance. Regular maintenance, such as oil changes and filter inspections, can prevent many common problems. Always follow the manufacturer’s guidelines for optimal performance and longevity of your vacuum pump.

Leave a comment